Aguirre-Zapata, E., & García-Tirado, J. F. (2016). Monitoring Plasma Glucose Concentration from Interstitial Glucose Measurements for Patients at the Intensive Care Unit. Ingenierías USBMed, 7(2), 7–13. https://doi.org/10.21500/20275846.2617
Términos de licencia

Esta revista provee acceso libre inmediato a su contenido bajo el principio de hacer disponible gratuitamente las investigaciones al publico y apoyando un mayor intercambio de conocimiento global. 

Por tanto se acoge a la Licencia Creative Commons 4.0 Atribución- no comercial-sin derivadas (by-nc-nd): permite copiar y redistribuir el material en cualquier medio o formato, No se permite un uso comercial de la obra original ni de las posibles obras derivadas,  Si remezcla, tansforma o crea a partir del material, no podrá distribuir el material modificado.
 

Costos de procesamiento y presentación de los artículos

El procesamiento y publicación en Ingenierías USBMed no tiene costo.

Política de acceso abierto

Ingenierías USBMed proporciona un acceso abierto inmediato a su contenido, basado en el principio de ofrecer al público un acceso libre a las investigaciones ayudando a un mayor intercambio global de conocimiento. Por tanto se acoge a la Licencia Creative Commons 4.0 Atribución- no comercial-sin derivadas (by-nc-nd): permite copiar y redistribuir el material en cualquier medio o formato, No se permite un uso comercial de la obra original ni de las posibles obras derivadas,  Si remezcla, tansforma o crea a partir del material, no podrá distribuir el material modificado.

Derechos de Autor (Copyrigt)

La totalidad de los contenidos de Ingenierías USBMed, e-ISSN 2027-5846 están registrados y protegidos por las leyes de protección de la propiedad intelectual. Los derechos de propiedad intelectual de cada artículo son cedidos por sus autores a Ingenierías USBMed. Al someter el manuscrito, y únicamente en caso de ser aceptado para publicación, los autores aceptan que el copyright de su artículo queda transferido a Ingenierías USBMed. No obstante, se consideran todas las solicitudes de autorización por parte de los autores con fines de reproducción de sus artículos. Igualmente, Ingenierías USBMed otorga permiso de acceso para usuarios y bibliotecas. Ingenierías USBMed apoya el libre acceso a la literatura científica dicho copyright pide el respeto de los derechos morales, principalmente el reconocimiento de su autoría y el respeto a la integridad de la obra, evitando dentro de lo posible alteraciones, traducciones o falsificaciones. Al ser Ingenierías USBMed una publicación electrónica de carácter científico que publica trabajos de investigación científica y tecnológica, artículos de reflexión o artículos de revisión, el objetivo prioritario tanto de los los autores como de Ingenierías USBMed es lograr la mayor difusión de los artículos, para lo cual los autores ceden a Ingenierías USBMed sus derechos, únicamente a cambio del reconocimiento intelectual, moral y laboral, al considerarse que es una materia no de ocio o entretenimiento, sino de fuerte interés social, por su carácter científico.

Política Ética

Los autores deben actuar de forma ética en los procesos requeridos para la publicación de sus artículos en Ingenierías USBMed. Para esto, los autores y miembros de la revista se deben acoger a la politica de Ética editorial de la Editorial Bonaventuriana, disponible en el siguiente link: Manual editorial

Responsabilidad de contenidos

El contenido de los artículos publicados por Ingenierías USBMed es de exclusiva responsabilidad del (os) autor(es) y no necesariamente refleja el pensamiento del comité editorial y científico de la revista Ingenierías USBMed. Los textos pueden reproducirse total o parcialmente citando la fuente.

Resumen

The glucose homeostasis is responsible for regulating the blood glucose concentration around 100 mg / dl. When this physiological mechanism is broken due to the inability of the pancreas to produce insulin, an increase of the blood glucose levels is produced and patients are diagnosed with Diabetes Mellitus. In recent years, some research has directed towards the creation of an artificial pancreas that allows automatically the regulation of glucose levels in blood. However, one of the greatest difficulties in achieving this objective, is that not all internal variables of the mathematical model associated with the controller can be measured directly by physical sensors, either because there are no sensors for all variables, because existing sensors are not commercial, or because they are not viable from the economic point of view. Therefore, it is necessary to use estimation schemes to reconstruct the unknown states by measuring the interstitial glucose , in the case of the glucose-insulin system. However, the delay between plasma glucose and interstitial glucose has a negative effect on the performance of state estimators, so the treatment of this delay is necessary either from the modeling process of the glucose-insulin system or by a modification of the estimation techniques. According to the results it can be inferred that in the scenario at which the concentration of blood glucose is assumed, the estimated values have upper and lower peaks that are unrealistic from a physiological point of view, this due to the negative effect of the delay in measurement. Otherwise, in the scenario where the interstitial glucose concentration is considered as the measured variable, including dynamics of the interstitial glucose, the estimator exhibits better performance and rapid convergence to the real states.

Palabras clave:

Referencias

[1] M. Shrayyef and J. Gerich, “Principles of diabetes mellitus,” in Principles of Diabetes Mellitus, P. Leonid, Ed. 2010, pp. 19–35.

[2] J. Aldworth, N. Al Bache, M. H. Hegelund, S. M. Hirst, U. Linnenkamp, D. Magliano, F. Oomatia, C. Patterson, N. Peer, A. Pritulskiy, M. M. Al Saleh, E. Shelestova, T. Tamayo, J. Usher-Smith, Z. Xiuying, and Samrawit Yisahak, IDF Diabetes Atlas, 7th ed. 2015.

[3] J. Preiser, J. G. Chase, R. Hovorka, J. I. Joseph, J. S. Krinsley, C. De Block, T. Desaive, L. Foubert, and P. Kalfon, “Glucose Control in the ICU : A Continuing Story,” J. Diabetes Sci. Technol., vol. 10, no. 3, pp. 1–10, 2016.

[4] V. den Berghe Greet, W. Pieter, W. Frank, V. Charles, B. Frans, S. Miet, V. Dirk, F. Patrick, L. Peter, and B. Roger, “Intensive Insulin Therapy in Critically Ill Patients,” N. Engl. J. Med., vol. 345, no. 19, pp. 1359–1367, 2001.

[5] P. Kalfon, B. Giraudeau, C. Ichai, A. Guerrini, N. Brechot, R. Cinotti, P.-F. Dequin, B. Riu-Poulenc, P. Montravers, D. Annane, H. Dupont, M. Sorine, and B. Riou, “Tight computerized versus conventional glucose control in the ICU: a randomized controlled trial,” Intensive Care Med., vol. 40, no. 2, pp. 171–181, 2014.

[6] T. N.-S. S. Investigators, “Intensive versus Conventional Glucose Control in Critically Ill Patients,” N. Engl. J. Med., vol. 360, no. 13, pp. 1283–1297, 2009.

[7] B. P. Kovatchev, M. Breton, C. Dalla Man, and C. Cobelli, “In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes,” J. Diabetes Sci. Technol., vol. 3, no. 1, pp. 44–55, 2009.

[8] L. Magni, D. M. Raimondo, C. Dalla Man, G. De Nicolao, B. Kovatchev, and C. Cobelli, “Model predictive control of glucose concentration in type I diabetic patients: An in silico trial,” Biomed. Signal Process. Control, vol. 4, no. 4, pp. 338–346, Oct. 2009.

[9] K. Lunze, T. Singh, M. Walter, M. D. Brendel, and S. Leonhardt, “Blood glucose control algorithms for type 1 diabetic patients: A methodological review,” Biomed. Signal Process. Control, vol. 8, no. 2, pp. 107–119, Mar. 2013.

[10] J. Clain, K. Ramar, S. R. Surani, W. W. Ave, and A. Pass, “Glucose control in critical care,” vol. 6, no. 9, pp. 1082–1091, 2015.

[11] C. Eberle and C. Ament, “The Unscented Kalman Filter estimates the plasma insulin from glucose measurement.,” Biosystems., vol. 103, no. 1, pp. 67–72, Jan. 2011.

[12] R. Gondhalekar, E. Dassau, and F. J. D. Iii, “Moving-horizon-like state estimation via continuous glucose monitor feedback in MPC of an artificial pancreas for type 1 diabetes,” 2014.

[13] R. Gondhalekar, E. Dassau, and F. J. Doyle, “State Estimation with Sensor Recalibrations and Asynchronous Measurements for MPC of an Artificial Pancreas to Treat T1DM,” 2014.

[14] Medtronic, “Por qué las lecturas del sensor son diferentes a las lecturas de GS.” .

[15] J. Lin, N. N. Razak, C. G. Pretty, A. Le, P. Docherty, J. D. Parente, G. M. Shaw, C. E. Hann, and J. G. Chase, “A physiological Intensive Control Insulin-Nutrition-Glucose ( ICING ) model validated in critically ill patients,” Comput. Methods Programs Biomed., vol. 102, no. 2, pp. 192–205, 2010.

[16] C. King, S. M. Anderson, M. Breton, W. L. Clarke, and B. P. Kovatchev, “Modeling of calibration effectiveness and blood-to-interstitial glucose dynamics as potential confounders of the accuracy of continuous glucose sensors during hyperinsulinemic clamp,” J. Diabetes Sci. Technol., vol. 1, no. 3, pp. 317–322, 2007.

[17] D. Simon, Optimal state estimation: Kalman, H infinity, and nonlinear approaches. John Wiley & Sons, 2006.

[18] M. Breton and B. Kovatchev, “Analysis, modeling, and simulation of the accuracy of continuous glucose sensors,” J. Diabetes Sci. Technol., vol. 2, no. 5, pp. 853–862, 2008.

[19] P. J. Stout, N. Peled, B. J. Erickson, M. E. Hilgers, J. R. Racchini, and T. B. Hoegh, “Comparison of glucose levels in dermal interstitial fluid and finger capillary blood,” Diabetes Technol. Ther., vol. 3, no. 1, pp. 81–90, 2001.

Descargas

Los datos de descargas todavía no están disponibles.

Citado por